STANDARD FEATURES S S S S S S S S S S S S S S S S S S S S S S S S Multi--tap ECM (electronic commutating motor) motors -- all sizes Integrated motor controls, with 90--sec off TDR function, have replaced integrated circuit board Five available speed tags to meet a wide range of applications Large, grooved tube, louvered fin coils Efficient, quiet, time--tested blower housings and diffusers Sturdy, drainable condensate pans Cabinet construction features innovations designed to prevent cabinet sweating Teste
MODEL NUMBER NOMENCLATURE 1 F 2 B 3 4 4 C 5 N 6 F 7 0 8 1 9 8 10 0 Product F = Fan Coil 11 0 12 0 Heating Size 00 = No Heat 05 = 5 kW 75 = 7.
DIMENSIONS A150081 Fig.
DIMENSIONS (cont.) A150082 Fig.
DIMENSIONS (cont.) A150083 Fig.
DIMENSIONS (cont.) A150084 Fig.
DIMENSIONS (cont.) A150085 Fig.
DIMENSIONS (cont.) A150086 Fig.
PHYSICAL DATA ORDERING NO. NOMINAL COOLING CAPACITY (Btuh) FB4CN(F,P)018L DIMENSIONS Height Width Depth SHIPPING WEIGHT 18,000 42--- 11/16 in. 1084mm 14--- 5/16 in. 363mm 22--- 1/16 in. 560mm 112 lb 51 kg FB4CNF024L 24,000 42--- 11/16 in. 1084mm 14--- 5/16 in. 363mm 22--- 1/16 in. 560mm 112 lb 51 kg FB4CNP025L 24,000 49--- 5/8 in. 1260mm 17--- 5/8 in. 447mm 22--- 1/16 in. 560mm 122 lb 55 kg FB4CN(F,P)030L 30,000 49--- 5/8 in. 1260mm 17--- 5/8 in. 447mm 22--- 1/16 in.
PERFORMANCE DATA FB4C AIRFLOW PERFORMANCE (CFM) MODEL & SIZE FB4C 018 FB4C 024 & 025 FB4C 030 FB4C 036 FB4C 042 FB4C 048 FB4C 060 FB4C 061 BLOWER SPEED Tap 5 Tap 4 Tap 3 Tap 2 Tap 1 Tap 5 Tap 4 Tap 3 Tap 2 Tap 1 Tap 5 Tap 4 Tap 3 Tap 2 Tap 1 Tap 5 Tap 4 Tap 3 Tap 2 Tap 1 Tap 5 Tap 4 Tap 3 Tap 2 Tap 1 Tap 5 Tap 4 Tap 3 Tap 2 Tap 1 Tap 5 Tap 4 Tap 3 Tap 2 Tap 1 Tap 5 Tap 4 Tap 3 Tap 2 Tap 1 0.
PERFORMANCE DATA (cont.
PERFORMANCE DATA (cont.) GROSS COOLING CAPACITIES (MBH) -- PURONR REFRIGERANT 1600 FB4C 060 1750 2000 1600 FB4C 061 1750 2000 72 / 22 67 / 19 62 / 17 72 / 22 67 / 19 62 / 17 72 / 22 67 / 19 62 / 17 72 / 22 67 / 19 62 / 17 72 / 22 67 / 19 62 / 17 72 / 22 67 / 19 62 / 17 106 86 68 113 92 73 124 101 80 109 89 71 117 95 76 129 105 84 CFM --- Cubic Ft per Minute SHC --- Gross Sensible Capacity 1000 Btuh 54 56 56 58 59 61 64 66 67 57 58 59 61 62 63 67 69 70 0.00 0.04 0.04 0.00 0.04 0.05 0.00 0.06 0.
PERFORMANCE DATA (cont.) ELECTRIC HEATER STATIC PRESSURE DROP (in wc) FB4C 018 --- 036 FB4C 042 --- 061 kW EXTERNAL STATIC PRESSURE CORRECTION HEATER ELEMENTS 0 0 +.02 1 3, 5 +.01 2 8, 10 3 4 HEATER ELEMENTS kW EXTERNAL STATIC PRESSURE CORRECTION 0 0 +.04 2 8, 10 +.02 0 3 9, 15 0 9, 15 –.02 4 20 –.02 20 –.04 6 18, 24, 30 –.
PERFORMANCE DATA (cont.) ESTIMATED SOUND POWER LEVEL (dBA) CONDITIONS FB4C OCTAVE BAND CENTER FREQUENCY* CFM Ext Static Pressure 63 125 250 500 1000 2000 4000 600 0.25 64.7 60.7 56.7 53.7 51.7 49.7 45.7 024/025 800 0.25 66.0 62.0 58.0 55.0 53.0 51.0 47.0 030 1000 0.25 67.0 63.0 59.0 56.0 54.0 52.0 48.0 036 1200 0.25 67.8 63.8 59.8 56.8 54.8 52.8 48.8 042 1400 0.25 68.4 64.4 60.4 57.4 55.4 53.4 49.4 048 1600 0.25 69.0 65.0 61.0 58.0 56.0 54.
18.0 18.0 22.5 22.5 5 5 8 8 9 9 10 10 15 15 15 18 20 20 24 24 30 30 KFCEH2401C051 KFCEH2401C052 KFCEH0801N08 KFCEH2501C08 KFCEH2901N09 KFCEH2901N09** KFCEH0901N10 KFCEH2601C10 KFCEH3001F15 KFCEH3101C15 KFCEH1601315 KFCEH2001318 KFCEH3201F20 KFCEH3301C20 15.0 13.5 11.3 11.3 11.3 7.5 7.5 6.8 6.8 6.0 6.0 3.8 3.8 3.
HEATER ELECTRICAL DATA ELECTRIC HEATER INTERNAL PROTECTION HEATER kW PHASE FUSE QTY/SIZE CKT BKR* QTY/SIZE 5 1 — 1/60 8 1 — 1/60 9 1/3 — — 10 1 — 1/60 15 1 2/30–2/60 2/60 15 3 — — 18 3 — — 20 1 4/60 2/60 24 1/3 6/60 — 30 1/3 6/60 — *All circuit breakers are 2 pole. When using units with 20-- , 24-- , and 30-- kW electric heaters, maintain a 1-- in.