Use and Care Manual
Page 30mrcool.com
Indoor Unit Installation
Minimum & Maximum height of vertical pipe section when connecting multiple units & outlet of the
drainpipe is higher than cassette drain outlet port:
Minimum height of vertical pipe section when connecting multiple units & outlet of the drainpipe is
lower than cassette drain outlet port:
0 to 20.8 in
(0 to 53 cm)
≥4 in
(≥10 cm)
3. Now, pass the drain pipe through the wall hole to
the exterior of the house. If it has not already
been done, also pass the end of the DIYPRO™
Cable through the wall hole to the exterior as well.
4. Position the drainpipe and line set so they pass
through the wall hole in the orientation shown
below in Fig. 5.21.
Refrigerant
Line Set
Drainpipe
Wall Hole
NOTE ON DRAINPIPE OUTLET
The drainpipe should exit the wall hole and
run in a way that allows the condensate to
flow freely and be discharged from the outlet
onto the ground. The drainpipe outlet should
be at least 1.9 in (5 cm) above the ground. If
the drainpipe touches the ground it could
become blocked and cause the unit to
malfunction. If you discharge the condensate
directly into the sewer, ensure that the drain
has a U or S pipe to catch any odors that
might otherwise come back into the home.
Please refer to Figs. 5.22a - 5.22d on the right
as a guide when determining how the
drainpipe should exit your application.
Make sure there are
NO kinks or dents in
the hose to ensure
proper drainage .
NOT CORRECT
KINKS in the
drainpipe will
create water traps
NOT CORRECT
DENTS in the
drainpipe will
create water traps
NOT CORRECT
DO NOT place the
end of the drain
pipe in water or in
containers that collect
water. This will prevent
proper drainage.
Fig. 5.20
Fig. 5.19
Fig. 5.21
Fig. 5.22a
Fig. 5.22b
Fig. 5.22c
Fig. 5.22d