Instructions / Assembly

Page 34mrcool.com
Outdoor Unit Installation
UNIT MOUNTING DIMENSIONS
The following is a list of different outdoor unit
sizes and the distance between their mounting
feet. Prepare the installation base of the unit
according to the dimensions in the table below,
using the illustrations of the unit above (Fig 6.5)
as a guide to correspond with the table.
Step 3: Anchor Outdoor Unit
The outdoor unit can be anchored to the ground or
to a wall-mounted bracket using M-10 bolts. Prepare
the installation base of the unit according to the
dimensions below. For instructions of how to mount
the unit to a wall mounted bracket, please refer to the
following page.
If you are installing the outdoor unit on the
ground, or a concrete mounting platform, use
the following steps:
1. Mark the positions for four expansion bolts
based on dimensions in the Mounting
Dimensions chart and illustrations above.
2. Pre-drill holes for expansion bolts.
3. Clean concrete dust away from the holes.
4. Place a nut on the end of each expansion bolt.
5. Hammer expansion bolts into the
pre-drilled holes.
6. Remove the nuts from the expansion bolts, and
place outdoor unit on bolts.
7. Put a washer on each of the expansion bolts,
then reinstall the nuts.
8. Using a wrench, tighten each nut until snug.
Outdoor Unit Dimensions:
Inches (Millimeters)
Width (W) x Height (H) x Depth (D)
Mounting Dimensions:
Inches (Millimeters)
Width (A) Depth (B)
37.24 in x 31.89 in x 16.14 in
(946 mm x 810 mm x 410 mm)
26.50 in
(673 mm)
DIY-MULTI3-27HP230C
DIY-MULTI4-36HP230C
37.24 in x 31.89 in x 16.14 in
(946 mm x 810 mm x 410 mm)
26.50 in
(673 mm)
15.87 in
(403 mm)
35.04 in x 26.50 in x 13.46 in
(890 mm x 673 mm x 342 mm)
26.10 in
(663 mm)
DIY-MULTI2-18HP230C
13.93 in
(354 mm)
35.04 in x 26.50 in x 13.46 in
(890 mm x 673 mm x 342 mm)
26.10 in
(663 mm)
DIY-18-HP-C-230C
13.93 in
(354 mm)
15.87 in
(403 mm)
DIY-MULTI5-48HP230C
37.48 in x 52.48 in x 16.34 in
(952 mm x 1333 mm x 415 mm)
24.96 in
(634 mm)
15.90 in
(404 mm)
Outdoor Unit
Model #:
Single
Zone
Multi
Zone
W
W
H
D
Air Inlet
A
B
Air Outlet
Air Inlet
Fig. 6.5
TOP VIEW
FRONT VIEW
H
Single-Zone: 18K
Multi-Zone: 18K, 27K, & 36K
Multi-Zone: 48K
When drilling into concrete, eye protection is
recommended at all times.
WARNING