How to Guide
1. Carefully roll the excess tubing and place it 
behind the condenser.
2. Attach the bundle connections to the outside 
condenser.
STEP 5 - outside
Carefully unroll to indoor 
handler connection
Connect directly to 
exterior condensor
Keep excess coiled
Radius
3. Using two crescent or adjustable wrenches, 
screw the quick connect components together. Use 
one to hold the valve and keep it from twisting and 
the other to 
tighten the fitting. 
4. See manual for 
tool and torque 
requirements. 
Improper 
connection can 
void warranty.
1. Remove the brass caps from the valves on the 
exterior condenser unit. 
2. Use an allen wrench to open each connection 
valve counter clockwise until it stops turning. Be 
sure not to exert excessive force on the valve. You 
may hear a soft hissing sound as a slight amount of 
R-410a refrigerant exits the condenser.
3. Perform the same action for the Main Valves 
(King valves) after all other valves have been 
opened.
4. Apply soapy water or leak detection spray to the 
Quick Connect
® 
fittings. If you see bubbles, this 
indicates there is a leak. Tighten the connection 
accordingly until the bubbles are gone. 
STEP 6 - outside