How to Guide
STEP 1 - inside STEP 3 - inside
STEP 2 - inside
1. Drill screw holes at the indicated points into 
studs.
2. Remove the bracket from the rear of the interior 
air handler.
3. Screw the metal bracket to the wall according to 
the template.
4. Use a level to 
ensure the 
mounting plate is 
flush and level.
1. Locate the wall template.
2. Place the template on the wall at the installation 
location. 
3. Use the template 
to mark the drill 
points and wall hole 
site.
4. Remove the template.
Wall
Indoor Outdoor
0.2 - 0.3in
(5 - 7 mm)
1. Drill a 3.5 inch diameter hole through the wall, at 
a slightly downward angle, to accommodate the 
line set, condensate drain line and communication 
cable to the exterior condenser.
2. Use the vinyl tape to wrap the line set, 
condensate drain line and communication cable 
into a bundle. The drain MUST be on the bottom.
3. Install the wall sleeve into the wall hole and 
push the bundle through it.
condensate
drain line