5. Now remove the cover on the top valve using a 19 mm 
open ended wrench (i.e. crescent or adjustable). Open the 
valve by turning it counter-clockwise as far as it will go 
using a 5 mm Allen key. The valve is now open. If the valve 
is not opened fully, the system may malfunction and suffer 
damage. Screw the cover back on to the top valve and 
tighten it well to ensure that it is properly sealed.
CAUTION
Page 29
mrcool.com
Refrigerant Piping Connection
6. Now remove the cover on the bottom valve using a 19 
mm crescent (or adjustable) wrench. Open the valve by 
turning it counter-clockwise as far as it will go using a 5 
mm Allen key. The valve is now open. If the valve is not 
opened fully, the system may malfunction and suffer 
damage. Screw the cover back on to the bottom valve 
and tighten it well to ensure that it is properly sealed.
7. After completing steps 1- 6, check that all the connections are sealed correctly using leak detection spray or soap suds. 
If any bubbles form, the system has a leak and the screw connectors must be retightened using a crescent or adjustable 
wrench.
8. Start the equipment so that the operating pressures build 
up inside the system. Check all the connectors again for 
signs of leaks
a)  during cooling mode
b)  in heating mode.
NOTE
If any bubbles form, the system has a 
leak and the screw connectors must be 
retightened.
All of these steps must be completed BEFORE powering on the unit. Failing to do so 
could damage the unit.