Indoor Unit Installation
3. Using open ended wrenches (i.e. crescent or adjustable), 
hold the points marked “1” and turn the nuts only at the 
points marked “2”  (select the appropriate wrench according 
to the dimensions of the connector). 
Outer Diameter 
of Pipe (in/mm)
Stamp
Tightening Torque 
(lb·ft / N·m)
Add. Tightening Torque 
(lb·ft / N·m )
Ø0.25” (Ø 6.35mm)
1/4”
3/8”
1/2”
5/8”
11 lb•ft (14.91 N·m)
11.8lb•ft (16 N·m)
Ø0.375” (Ø 9.52mm)
18.4 lb•ft (24.95 N·m)
19.18lb•ft (26 N·m)
Ø0.5” (Ø12.7mm)
25.8 lb•ft (34.98 N·m)
26.55lb•ft (36 N·m)
Ø0.63” (Ø16mm) 33.19 lb•ft (45 N·m) 34.67lb•ft (47.01N·m)
 TORQUE REQUIREMENTS 
1.  Excessive force can break the nut or damage the refrigerant piping. You must not exceed torque 
requirements shown in the table below. 
2. You can find the Outer Pipe Diameter stamped (in inches) on the valve set of the condenser.  Refer to 
this when finding and applying the torque values in the table below. 
3. Note that there may be differences in Torque Wrenches (i.e. automotive torque wrench versus a HVAC 
torque wrench) and that a socket style wrench cannot be used here.
4. Ensure that the screw connectors do not skew as you 
tighten them and work quickly.
5. After finishing the connection, use the tape to wrap the 
refrigerant pipe and connecting cable together.
6. After you finish connecting the quick connectors, 
pass the drain hose and refrigerant pipes through 
the wall hole as shown here.
7 In order to prevent Quick Connect® parts from 
being exposed to air, sound deadening pads 
should be used during the installation.
9. Wrap up the Quick Connect® with the black 
insulation material. For the top exposed part, use the 
white insulation material (supplied in Accessories box) 
to wrap completely as shown here.
10. At last, use tape to wrap the refrigerant pipe and 
connecting cable together.
IMPORTANT: Before you continue, it is essential that 
you read the following instructions carefully.
The Quick Connect
®
 must be placed outside of the room. Using the wall hole sleeve, cap and neoprene to seal the 
wall hole. Both power cable and signal cable should be protected by the conduit.
NOTE: 
1 2
8.Wrap the Quick Connect® with the sound 
deadening pads, pack down the pads tightly as 
shown here.