Quick Start Guide
STEP 8 - Outside
1. Remove the electrical cover by removing the screws
holding it in place.
2. Wires and terminals that are numbered should be
matched and connected accordingly.
3. Terminal L1(A) of the outdoor unit must connect with
terminal 1 on the indoor unit. Continue to match zone to
zone for any additional connections.
4. Replace electrical cover and screw it back into place.
Refer to the diagrams / photo at the bottom left. For more
detailed instructions regarding the electrical connections,
please refer to the Installation Manual.
WARNING
BEFORE PERFORMING ANY ELECTRICAL WORK, TURN OFF ALL
POWER TO THE SYSTEM.
1. Wire colors of this series / model may differ from previous
models, other series and general conventions.
2. All wiring must be performed in accordance with the wiring
diagrams shown here and all municipal, state and federal
regulations.
4. This product is designed to run on 60Hz frequency which is
the North American standard.
5. A certified electrician is required to supply power from a
disconnect of an appropriate rating - see manual.
STEP 7 - outside
Quick Connect® Line Set
(refrigerant pipe)
Pat. https://mrcool.com/mrcool-patents/
wrap from
bottom to top
to ensure tape
overlap sheds
rain/water
wrap piping all the way to
exterior wall hole
Quick Connect
®
connections
keep line excess
bundled and coiled
then wrap together
Wrap the Quick Connect®
connections with the black
sound deadening pads. Then
place insulation over them
before line set is wrapped
Up to Three Zones
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
Up to Four Zones
L2
L1
LPPUS REWOP Y
L1(A)
L2(A)
S(A)
L1(B)
L2(B)
S(B)
1(C) 2(C) 3(C) 1(D) 2(D) 3(D)
TO A
TO B
TO D
TO C
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL