Install Manual

Page 19
mrcool.com
Indoor Unit Installation
MOUNTING PLATE DIMENSIONS
In order to ensure that you have ample room to
mount the indoor unit, the diagrams to the right
with the following dimensions:
Height & Width of mounting plate
Height & Width of indoor unit relative to plate
Recommended position of wall hole
Relative distances between screw/mounting
holes
Do not attempt a left rear wall hole.
Correct orientation of Mounting Plate
NOTE: Use a level in order to ensure your
mounting plate is mounted to the wall with
the correct orientation shown above.
Correct Angle to Drill Wall Hole
Keep in mind that the hooks on the mounting plate
are smaller than the holes on the back of the unit. If
you find that there is not enough room to connect
embedded pipes to the indoor unit, it can be adjusted
left or right by 1.25-1.95 in (30-50 mm), depending on
the model.
UNIT IS ADJUSTABLE
(30-50 mm)
(30-50 mm)
Adjustment range of indoor unit to the left or right
Wall
Indoor
Outdoor
Fig. 5.3
0.2 - 0.3in
(5 - 7 mm)
Drill used to
create wall
hole
Wall Hole Sleeve Installation
Fig. 5.4
Fig. 5.5
Series 9K & 12K Models
7.55 in (192 mm)
9.15 in (232 mm)
5.05 in (128 mm)
1.7 in (43 mm)
11.7 in (297 mm)
31.6 in (802 mm)
42.5 in (1080 mm)
49.55 in (1259 mm)
1.7 in (43 mm)
1.7 in (43 mm)
8.6 in (219 mm)
21.77 in (553 mm)
25.3 in (643.6 mm)
11.8 in (300 mm)
13.2 in (335 mm)
Right rear wall hole
3.5 in (90 mm) Diameter
Series 36K Models
1.85 in (47 mm)
3 in (76 mm)
2.1 in (53.5 mm)
1.85 in (47 mm)
5.85 in (148.7 mm)
5.95 in (148.7 mm)
6.85 in (174.3 mm)
14.25 in (362mm)
Right rear wall hole
3.5 in (90 mm) Diameter
15.3 in (389 mm)
13.05 in (332 mm)
10.1 in (257 mm)
2.05 in (52 mm)
Outline of indoor unit
when mounted to plate
16.8 in (426 mm)
Series 18K & 24K Models
Outline of indoor unit
when mounted to plate
Right rear wall hole
3.5 in (90 mm) Diameter
Outline of indoor unit