How to Guide
1 2
4. Snap the air handler onto the wall bracket. 
STEP 3 - continued
STEP 4 - outside
STEP 4 - continued
1. Place outside condenser unit firmly on the 
ground or attach it to a secure metal wall bracket 
or pad. Drain pipe is not required and can be 
installed as necessary only if elevated.
2. Remove the plastic seals from the indoor 
handler refrigerant lines.
3. Carefully unroll the amount of Quick Connect® 
line set needed to connect the indoor handler 
fittings and the outside condenser. Leave the coiled 
portion stored near the condenser.
4. Align the Quick Connect® refrigerant lines to the 
matching indoor handler fittings. Tighten the first 
few threads by hand.
5. Using open ended wrenches (i.e. crescent or 
adjustable): hold the points marked “1” and turn 
the nuts only at the points marked “2” (Select the 
appropriate wrench according to the dimensions of 
the connector).  
6. Ensure that the screw connectors do not skew 
while working quickly to tighten them.
Ground Installed: 
12 in (30 cm)
Bracket Installed: 
6 in (15 cm)
clearance between 
back and wall
79in (200cm) 
in front
12in (30cm)
on left
24in (60cm)
above
24in (60cm) 
on right