Installation Guide
Page 19 mrcool.com
Indoor Unit Installation
5.1 Tools needed
You will require the following tools to carry out this 
installation work correctly:
•1x crescent wrench, 19 mm
•1x crescent wrench, 22 mm/24mm
•1x crescent wrench, 24 mm/27mm
•1x Allen key, 5 mm
•1x Philips screwdriver
•1x leak detection spray or alternatively soap suds 
(water/detergent mix)
5.2 Important information
•Follow the detailed instructions for connecting the 
refrigerant pipes to the indoor unit and outdoor unit. 
We can only provide a warranty if the lines are installed 
correctly as described in the instructions. 
•Do not remove the sealing caps and stoppers until 
immediately before you install the lines. 
•To prevent leaks, ensure that the quick-release screw 
connections are absolutely free of dirt. Moisture or 
foreign bodies will adversely affect the function of the 
quick-release connectors, leading to a risk of refrigerant 
loss (not covered by the warranty).
•Only install refrigerant lines outdoors in dry weather.
•The refrigerant lines must not be plasterred over after 
they are installed.
•Please make sure that refrigerant is never allowed to 
enter the environment. Improper handling of 
refrigerant may be harmful to health. Always wear 
work gloves and goggles when handling refrigerant.
•Do not smoke during the installation work. The 
equipment must never be o+perated without the 
refrigerant lines connected, otherwise the equipment 
will be damaged immediately.
•The screw connections may only be tightened using the 
appropriate open ended (i.e. crescent or adjustable) wrench.
Step 5: Connect Refrigerant Piping to Indoor Unit Refrigerant Pipe Connectors (both ends):
NOTE: To distinguish the connectors to be 
connected to the indoor unit and outdoor unit, 
the connectors of the refrigerant pipe has been 
labelled “A”, “B”,“C”and “D”. Ensure the marks 
on the connectors are the same, to the indoor’s 
and outdoor’s respectively during connection.
If the screw connections are tightened with too little 
torque, they will leak. If they are tightened with too 
much torque, the screw connections may suffer 
damage. Please refer to the torque requirements 
section for more information. If you are not confident 
about connecting the refrigerant line connectors 
yourself, it is imperative that you contact the 
MRCOOL® customer service team or a professional.
IMPORTANT: 
The EQ valves are only designed for one-time 
installation. Their seal can not be guaranteed if they are 
installed on more than one occasion. This will also void 
the warranty.
5.3 Connecting the refrigerant pipes to the 
indoor unit
1.
 Do not remove the plastic seals from the indoor 
equipment and the appropriate refrigerant pipe 
until immediately before you connect them.
2. Align the refrigerant pipes correctly, make sure 
the dimensions of the connecting refrigerant pipe 
are the same. Place the screw connector on the 
refrigerant pipes just on to the thread on the 
indoor equipment and tighten the first few 
threads by hand.
IMPORTANT:
Before you continue, it is essential that you read 
the following instructions carefully.