Installation Manual
2.1 Precautions for selecting the location
2.2 Figure of body size
2. OUTDOOR UNIT INSTALLATION
1) Choose a place solid enough to bear the weight and vibration of 
 the unit, where the operation noise will not be amplified.
2) Choose a location where the hot air discharged from the unit or 
 the operation noise will not cause a nuisance to the neighbours 
 of the user.
3) Avoid places near a bedroom and the like, so that the operation 
 noise will cause no trouble.
4) There must be sufficient spaces for carrying the unit into and out 
 of the site.
5) There must be sufficient space for air passage and no 
 obstructions around the air inlet and the air outlet.
6) The site must be free from the possibility of flammable gas 
 leakage in a nearby place.
7) Install units, power cords and inter-unit wire at least 9.8ft away from 
 television and radio sets. This is to prevent interference to images 
 and sounds. (Noises may be heard even if they are more than 9.8ft 
 away depending on radio wave conditions.)
8) In coastal areas or other places with salty atmosphere of sulfate 
 gas, corrosion may shorten the life of the air conditioner.
9) Since drain flows out of the outdoor unit, do not place under the 
 unit anything which must be kept away from moisture. 
Cannot be installed hanging from ceiling or stacked.NOTE:
When operating the air conditioner in a low outdoor ambient 
temperature, be sure to follow the instructions described below.
- To prevent exposure to wind, install the outdoor unit with its suction 
 side facing the wall.
- Never install the outdoor unit at a site where the suction side may 
 be exposed directly to wind.
- To prevent exposure to wind, it is recommended to install a baffle 
 plate on the air discharge side of the outdoor unit.
- In heavy snowfall areas, select an installation site where the snow 
 will not affect the unit.
CAUTION
- Construct a large canopy.
- Construct a pedestal.
Install the unit high enough off the 
ground to prevent burying in snow.
MODEL A
780 548 266 300 241 250 540
B C D E F H
7
9K~18K
760 530 290 315 270 285 590
810
845
549
560
325
335
350
360
305
312
310
320
558
700
Unit:mm
A
B
F
E
C
D
H
(in=mm/25.4)
For more info visit www.mrcool.com