Installation Manual
2
Indoor unit installation;
Outdoor unit installation;
Install the refrigerant pipe;
Connect the drain pipe;
Electric wiring work;
Installation of the decoration panel;
Test  operation.
If the refrigerant leaks during installation, ventilate the area 
immediately.
Toxic gas may be produced if the refrigerant comes into the 
place contacting with fire.
The temperature of refrigerant circuit will be high, please keep 
the interconnection cable away from the copper tube.
After completing the installation work, check that the refrigerant 
does not leak.
Toxic gas may be produced if the refrigerant leaks into the 
room and comes into contact with a source of fire, such as a 
fan heater, stove or cooker.
Ground the air conditioner.
Do not connect the ground wire to gas or water pipes, lightning 
rod or a telephone ground wire. Inappropriate grounding may 
result in electric shocks.
Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric 
shocks.
Connect the outdoor unit wires, then connect the indoor unit 
wires. 
You are not allowed to connect the air conditioner with the 
power supply until the wiring and piping is done.
While following the instructions in this installation manual, install 
drain piping in order to ensure proper drainage and insulate 
piping in order to prevent condensation.
Improper drain piping may result in water leakage and property 
damage.
Install the indoor and outdoor units, power supply wiring and 
connecting wires should be at least 3.3ft
 away from 
televisions or radios in order to prevent image interference or 
noise.
Depending on the radio waves, a distance of 3.3ft
 may not 
be sufficient enough to eliminate the noise.
The appliance is not intended for use by young children or 
infirm persons without supervision.
Don't install the air conditioner in the following circumstance:
The appliance shall be installed in accordance with national 
wiring regulations.
Do not operate your air conditioner in a wet room such as a 
bathroom or laundry room.
An all-pole disconnection device which has at least 0.1in / 3mm 
clearances in all poles, and have a leakage current that may 
exceed 10mA, the residual current device (RCD) having a rated 
residual operating current not exceeding 30mA, and 
disconnection must be incorporated in the fixed wiring in 
accordance with the wiring rules.
CAUTION
There is petrolatum  existing.
There is salty 
 air surrounding (near the coast).
There is caustic
 gas (the sulfide,
  for example) existing
in the air
 (near a hot
 spring).
The Volt
 vibrates violently (in
 the factories).
In buses or
 cabinets.
In kitchen where
 it is full
 of oil gas.
There is strong
electromagnetic wave existing.
There are inflammable
 materials or gas.
There is acid
 or alkaline liquid
 evaporating.
Other special conditions.
To install properly, please read this "installation manual" at 
first.
The air conditioner must be installed by qualified persons.
When installing the indoor unit or its tubing, please follow 
this manual as strictly as possible.
If the air conditioner is installed on a metal part of the 
building, it must be electrically insulated according to the 
relevant standards to electrical appliances.
When all the installation work is finished, please turn  on 
the power only after a thorough check.
Regret for no further announcement if there is any change 
of this manual caused by product improvement.
INSTALLATION INFORMATION
INSTALLATION ORDER
For more info visit www.mrcool.com