PROCEDURE:
o Press AIR Quick access button
o Otions connected with the
function will be displayed
o Press steel pattern value field
and enter its correct value
o Press aluminium pattern value
field and load its correct value
o If other materials patterns are used, fields connected with material den
sity should be changed
o press START field- scal eis ready for operating
o follow instruction given In Info
field on COMMAND
place steel pattern
After indication stabilization,
OK button should be
pressed
Place aluminium pattern
After indication stabilization, OK button should be pressed
Display measures air density automatically.
18.14. Formulations
Formulations enable max.10 mixtures preparing, each of them can
consist of max.20 ingredients. Each ingredient has its own name and
value that should be loaded into mixture.
First, a formulation should be created and then it should be recalled to be used.
Formulations creating is possible in internal formulation function menu. The operation
procedure is described in following part.
Quick access buttons connected with formulations function. Yes (visible) or No
(invisible) options should be chosen for each button.
Calibration
Meter clearing
Tare setting
ID definition
Tar recalling
Formulations base
Heading print
Statistics
Text foot print xxx Non-standard buttons
Quick access buttons use and operating is described In point 18.6. Weighing
operating mode parameters- buttons.
Other buttons should be used as instructed In point 18.7.