System information
- 65 -
After pressing the function’s symbol,
target Mount should be entered. The
value should be given as pieces number.
The value entered must be a complete
one, e.g. 50 pcs.
If loaded values has decimal places, scale
records only its complete value part.
While details counting, bar chart shows
current number In form of colourful
progress bar.
Permissible area- result is a correct one if
it is situated In tolerance+/- 10% in
relation to target mass.
− Number of pieces below
permissible area mass
− Number of pieces In tolerance
area +/- 10% in relation to
target mass
− Number of pieces beyond
permissible area
Caution:
If checkweighing and feeding functions are chosen at the same time,two bar charts are shown on
display.
18.9. Checkweighing
Checkweighing is a procedure of monitoring mass of loading, whose
bottom and top values are defined – they are so called checkweighing
thresholds marked as LO oraz HI.
Standard buttons connected with checkweighing function. Choose YES (visible) or NO
(invisible) option for each button.
Calibration /yes –no/
Meter clearing /yes –no/
Tare setting /yes –no/
ID definition /yes –no/