Specification Sheet

mr
.
steam
®
Sussman-Automatic Corp
®
hello@mrsteam.com www.mrsteam.com
43-20 34th Street, Long Island City, NY 11101, 1 800 76 STEAM I 9410 S. La Cienega Blvd. Inglewood CA 90301, 1 800 72 STEAM
6
3
/
8
"
(162)
Water Inlet
Control & Accessory
Connections
Steam Outlet
Safety Valve
Manual Drain Valve
2
3
/
8
"
(60)
25
1
/
8
"
(638)
4"
(100)
5
7
/
8
"
(150)
7
7
/
8
"
(200)
2
3
/
8
"
(60)
9
3
/
4
"
(248)
11"
(279)
16
1
/
2
"
(419)
20
3
/
4
"
(527)
1
3
/
8
"
(34)
1
7
/8
"
(48)
Optional
AutoFlush
MrSteam Standard Features
Stainless steel tank
Industrial, large diameter,
serviceable heating element
Modular Plug and Play connections
Electronic water-level control system
Full-port drain valve
Limited lifetime steam generator
parts warranty
Safety Features
Built-in, low-voltage 24-volt control
ASME safety valve
60-minute electronic countdown shutdown
with 75-minute limiting safety back-up
Locating and Installing the Steam Generator Unit
Select a location as near as practical
to the steam room, within 60 feet.
Typical locations include: closet,
heated attic or basement.
Do not install steambath generator
inside the steam room.
Do not install steambath generator
outdoors or wherever environmental
conditions may affect the safety and/
or performance of the generator.
Do not install steambath generator or
plumbing lines in unheated attic or
any locations where water could
freeze.
Required Plumbing
Steam Pipe (3/4" NPT) Drain (1" NPT)
Steam Head (1/2" NPT) Water Supply (3/8" NPT)
Safety Valve (3/4" NPT)
Electrical
All electrical wiring to be installed by a qualified
licensed electrician in accordance with National
Electrical Code and local electrical code.
Power Wiring
1. Check power voltage. Use 240V rated unit when sup-
ply matches rating of unit before installation.
2. Use minimum 90° C/300 V rated insulated copper
conductors only, type THHN or equal sized in
accordance with National Electrical Code and local
electrical code for the Amps in Ampere Chart. If al-
lowed by code, NM cable may require a larger wire size
than as listed on the chart.
3. Connect suitably sized equipment grounding wire to
ground terminal provided.
4. Install a separate circuit breaker between supply and
unit. Provide a power supply disconnect within sight of
the steam generator or one that is
capable
of being
locked
in
the
open position.
Do not install steambath generator near
flammable or corrosive materials or
chemicals or in areas having a high
concentration of chlorine.
Install steambath generator on a solid and
level surface or securely mounted to a wall
using the keyhole slots provided.
Install steambath generator in an upright
position only.
Provide a minimum of 18 inches on the left
side and 21 inches at the top of the steam
generator or as required for servicing.
The minimum clearance from combustible
surfaces is zero all around.
TS0080-MX4E-6E REV 2.21
mr
.
steam
®
Technical Specifications
______________________________________________________
Model MX4E-6E
FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT NOTE: FOR SAFE
AND TROUBLE FREE INSTALLATION
visit mrsteam.com or refer to the
manual provided with the unit.
Required Equipment: iSteam3, AirTempo, iTempo, iTempoPlus
Controls Optional Equipment: iGenie, AudioWizard, ChromaSteam,
HomeWizard, Recessed Light, MS Light, MS Wallseat, AutoFlush,
Condensation Pan, AromaSteam
AMPERE CHART
1 97 1
3 56 4
1 84 3
3 48 6
3 24 10
1 116 1/0
3 67 4
1 100 1
3 58 6
3 29 10
1 145 3/0
3 84 2
1 125 2/0
3 73 3
3 36 8
208
240
480
208
240
480
208
240
480
20
24
30
678
822
964
MX4E
MX5E
MX6E
MODEL
NO.
Vol
(CU. FT.)
KW
Volts
Phase
Amps
Wire Size
(AWG) for
25
o
C
MODEL VOLTAGE* PHASE OPTIONS
I
I
MX4E
I
I
B=208
I
I
1-Single Phase
I
I
MX5E
I
I
C=240
I
I
3-Three Phase
I
I
Express
Steam
I
I
MX6E
*Contact Mr. Steam for other voltages
Notes:
Location:
Architect:
Engineer:
Contractor:
Date:
Submitted by:
I F=480