Submittal Sheet
Table Of Contents
Linear Steam Head
TS0067
REV 6.20
mr
.
steam
®
Sussman-Automatic Corp
®
hello@mrsteam.com www.mrsteam.com
43-20 34th Street, Long Island City, NY 11101 TEL: 1 800 76 STEAM
9410 S. La Cienega Blvd. Inglewood CA 90301 TEL: 1 800 72 STEAM
Linear Steamhead Installation
(
3
⁄4" NPT)
IMPORTANT: Do not disassemble steamhead. MrSteam’s
steamhead is shipped fully assembled and requires no
additional assembly.
Locate steamhead 6-12 inches above floor, except for
tub/shower enclosures; install 6 inches above tub top edge.
MODEL PROJECT INFORMATION
104480
For MS90 - MSSUPER3
Two
required for MX4, MX5 and MX6.
Notes:
Location:
Architect:
Engineer:
Contractor:
Submitted B y:
Date:
FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION visit mrsteam.com
before installation to download the Installation, Operation and Maintenance Manual or refer to the manual provided with the unit.
• Quiet,
even distribution of steam
• No field assembly required
• Finished Look
• No moving parts
• Minimal profile
• Aroma Feature
®
®
q BB q BN q MB q ORB
q PB q PC q PN q SB
(continue on next page)
Flush or recess
1
8
"
STUD
Cement Board
Thin Set
Finished
Wall Surface
Steam Outlet Face
Silicone
Silicone
Figure 4
Flush or recess
1
8
"
STUD
Cement Board
Thin Set
Finished
Wall Surface
Steam Outlet Face
Silicone
Silicone
Figure 4
14"
Steam
Outlet
14
5
16
"
3/4" NPT
Steam Outlet Connection
Steam
Outlet
3/4”
NPT
Steam Outlet Connection
14
1/16”
14
”
Adjustment Screws
2
1
8
"
9
1
4
"
1
1
16
"
5
8
"
Slotted
Mounting Holes
Slotted
Mounting Holes
Slotted
Mounting Holes
Slotted Mounting
Holes
9
1/4”
1
1/16”
5/8”
2
1/8”
Technical Specifications
TS0085
6"-12"
Above Floor
STEAM
EMISSION ZONE
Steam Room
Interior
STEAM
EMISSION
Number Steam
Generator of Linear Emission
Model Steam Heads Zone
MS90-MS400 1 18”
Super1-Super3 1 24”
MX4-MX6 2 24”
• Because the steamhead and direct
steam emissions are very hot,
locate the steamhead where
incidental contact by bather with
the steamhead or direct steam
emission cannot occur.
• Linear Steam Head model
104480 is suitable for MrSteam
generator models MS90– 400,
MSSUPER1–3 and MX4-MX6.
• Two 104480 linear steamheads
must be used for models MX4, 5
& 6.
• Using model 104480 for any
steam generator model larger
than the MX6, or for any non
MrSteam brand generators may
result in an improper installation
or hazardous condition.
• For residential use only.
• Install in a upright orientation
only. Installation in a any other
orientation may concentrate the
steam and result in excessive
temperatures.
TS0085.qxp_Linear Steam Head 7/14/20 11:22 AM Page 1