8
Troubleshooting
TO AVOID ELECTRIC SHOCK, DISCONNECT POWER TO PUMP BEFORE SERVICING
METERING PUMP DOES NOT PRIME
1.
Check if voltage is available.
2.
Check liquid level in scent container. Replenish liquid, if necessary.
3.
Check for air bubbles in the suction hose or the pump head. To eliminate air bubbles see: Priming Pump.
4.
Check valves for contamination. Clean valves, if necessary.
5.
Check filter in container for contamination. Rinse filter under clean water.
Metering pump does not inject oil into steam room
1.
Check if voltage is available.
2.
Check liquid level in scent container. Replenish liquid, if necessary.
3.
Check for air bubbles in the suction hose or the pump head. To eliminate air bubbles see: Priming Pump.
4.
Check valves for contamination. Clean valves, if necessary.
5.
Check filter in container for contamination. Rinse filter under clean water.
6.
Check the pressure hose for kinking or jamming. Straighten or replace.
7.
Check if liquid is freely flowing through the atomizing nozzle when the metering pump is energized. Apply compressed
air through the atomizing nozzle. Attach the compressed air at the point of connection of the pressure hose.
8.
For eTempo/Plus: ensure the demand button light is on. the demand button light should be pressed during installation,
the light willl turn on. In the event of a power outage the button will need to be pressed again.
Metering pump oil delivery too much or too little
Contact Mr.Steam techincal service personnel at 1-800-76 STEAM (East Coast) or 1-800-72-STEAM (West Coast).
Technical Specifications
Dimensions: 7” L x 6.5” W x 4.5” H
___________________________________________
Weight: 5 pounds
___________________________________________
EN 60335
UL Listed
CSA Approved
___________________________________________
Motor voltage 120 VAC, 50/60 Hz
Power consumption, total [W] 12 Watt
List of Spare Parts
Description Part No.
Pump Head 103861
Pressure/Suction Hose EO1-1032
(ordered by the foot)
Eucalyptus oil, 1 liter MS OIL 1
Lavender oil, 1 liter MS OIL 2
Evergreen oil, 1 liter MS OIL 3
Energizing Mint oil, 1 liter MS OIL 4
Poho oil, 1 liter MS OIL 5
Atomizing Nozzle 103918
Oil Injector 103983
Filter 103987
WARNING
!