Installation Sheet

mr
.
steam
®
aromasteam Operation and Installation Instructions
______________________________________________________________________________________________
6
Contactor
Electrical Connection of AromaSteam
System
This AromaSteam system is factory
wired. If the power cord of the AromaSteam system is
damaged it must be replaced by the Sussman-Automatic
service department or similarly qualified personnel in
order to avoid risks. All electrical connections to be made
by a licensed, qualified electrician. Disconnect all power
to the steam generator before making power connec-
tions.
1.
Disconnect all power to the Mr Steam steambath gen-
erator and remove the top cover.
2. Run the request cable from the AromaSteam System
through one of the knockouts in the side of the
steambath generator. Use a strain relief bushing or
grommet to prevent chafing.
3. Locate the contactor inside the steambath generator
and identify the red and red/white wires. (NOTE:
Tempo generations use blue & white wires).
4. Remove those two wires from the contactor
and attach the request cable to those two
terminals.
5. Reconnect the red and red/white wires by attaching
them to the piggyback terminals on the request cable.
NOTE: When using generators hooked up in tandem the
AromaSteam steam system should be connected to the
contactor on the primary generator. The atomizing nozzle
should be connected to the main generator’s steam line.
Demand Button
ETEMPO/PLUS INSTALLATIONS:
1.
Locate the demand button on or near the pump brack-
et. The demand button will be used to turn on the
AromaSteam pump only during installation (and if
power is cut to the pump) as the AromaSteam pump is
controlled by the eTempo/Plus
TEMPO, TEMPO/PLUS AND ETEMPO INSTALLATIONS:
1.
Locate the demand button in a location accessible
to the steambather. Mr.Steam suggests adjacent to
the Tempo Controls.
2. A 7/8 inch hole is required for the demand button.
3. Fill the hole with silicone as required for a mois-
ture seal, care should be taken not to get silicone
on the adhesive on the back of the button.
CAUTION
!
Demand Button
(refer to Installation Instructions
for proper location)
AromaSteam
Plug
Connector Connector
120 VAC
Outlet
(grounded receptacle required)
Request Cable
24 VAC
to steam generator
(see below)
AromaSteam Wiring Schematic
Contactor
Contactor location in MS-65T- MS400T
and MS90E - MS400E
Contactor location in MSSUPER1T- MSSUPER6T
and MSSUPER1E- MSSUPER6E
Demand Cable
AromaSteam Connections when using
eTempo/Plus
®
Controls
For Tempo
®
, Tempo/Plus
®
, and eTempo
®
For Tempo
®
, Tempo/Plus
®
, and eTempo
®