Installation Guide
This fixture is suitable for use in damp locations. When using this fixture in a damp
location, it must be recess mounted in a ceiling where it is protected from moisture.
This fixture is IC rated for direct contact with insulation. This fixture is a Type IC fixture.
This fixture is rated and approved for direct contact with insulation.
Installation to be performed by a qualified and licensed electrician.
Rough-In
We recommend using the Rough-In Bracket provided.Before installing the ceiling backer board, lay out your
light locations and securely fasten the rough-in plate to your joists at each light location. The rough-in brackets
have convenient slots in them allowing you to make minor adjustments to the bracket positioning after you’ve
mounted them.
• Run your Wire to the Light Location
Run your electrical wire from the switch/dimmer location to your light fixture. Be sure to check your local
code for which type of wire to run, most electrical codes require NM (also called Romex), BX, or MC wire.
Leave about 12-16” of wire sticking out of your hole, which will give you enough wire to connect to your
driver box.
Before installing the ceiling backer board, double check the location of each light. Once the ceiling is closed
you won’t be able to adjust the positioning.
Install finished ceiling, cut out the holes for each light using the rough-in bracket as a template. Once the ceiling
is finished, install your lights by following the remainder of the installation instructions below.
• Make your Electrical Connections
Remove the wiring compartment plate on your junction box.
Make a knockout on your junction box and install the appropri-
ate type of connector. For NM/Romex wire, you will typically
use a NM/clamp connector. For BX or MC, you’ll use a con-
nector specific to the wire that you’ve used.
Bring your incoming wire into the junction box and strip the
black and white wires. Be sure to ground the driver box by
connecting the green ground wire on your driver box to your
incoming ground wire using UL listed wire nuts/connectors.
Connect the black wire in your driver box to the incoming hot/
line wire (usually black). Connect the white wire in your driver
box to the incoming neutral wire (usually white). Be sure to only make connections using UL Listed wire
nuts/connectors.
Once you’ve finished making your electrical connections, install your wiring compartment cover and snap it
shut.
• Connect the Driver to the Light
Connect the driver cable plug to the plug on your light. Be sure to pay close attention to the arrows lo-
cated on plug (there is one small arrow molded into the plug on the light side of the cable and one small
arrow molded into the plug on the driver side of the cable). These arrows must point towards each other.
WARNING
!
mr
.
steam
®
Recessed LED Light Installation
______________________________________________________________________________________________________________________
Model LEDLITE
Ratings:
120 VAC 230 mA
3000K color temperature
600 Lumens
Maximum ceiling thickness 1
1
/
4
”