Installation Sheet

AutoFlush
7
Optional AutoFlush
Operation
The optional AutoFlush System feature automatically drains the
Mr.Steam
®
system following each use. A time delay allows the water to
cool down (about two hours) before it drains by gravity for a safe and
gentle operation.
NOTE: If the Express Steam option has been installed, the
AutoFlush will drain for ten minutes then refill with fresh water
to begin the pre-heat cycle.
Installation Instructions
1. Plumbing to be performed by a qualified plumber and shall
be in accordance with applicable national and local codes. Unit drains
by gravity. A drain line that is lower than the
AutoFlush assembly must be available. The AutoFlush System
valve outlet is
1
2” NPT. Check plumbing code for
receptor, trap and vent requirements.
2. Use copper or brass nipple
1
2” NPT x 3
1
2” or longer
(not supplied) to connect AutoFlush valve to the
Drain Valve. An arrow on the bottom of the AutoFlush
indicates the direction of flow.
!
CAUTION
PROVIDE DRAIN PLUMBING ACCORDING TO LOCAL
CODES. PLUMB AS REQUIRED FOR AUTOFLUSH SYSTEM.
AutoFlush Shown
Fully Assembled
Drain Valve
(shown in open position)
DO NOT REMOVE DRAIN VALVE
Copper or Brass Nipple
1/2” x3 1/2” or longer
(not supplied)
Arrow indicates
correct direction
of flow
Plumb to
drain line
Steam Generator
69992_PUR_100431_MrSteam.indd 8 2013-11-15 07:34