Installation Sheet
Installing the iTempo
®
or iTempo Plus
®
Control
1. Firmly connect the connector to the control. Turn on
power to the steam generator and test the control
to verify correct connections. Test per instructions.
Proceed with installation and verification of proper
control function.
IMPORTANT: Turn power to the steam
generator OFF before installing the control.
Failure to turn the power OFF will result in an
inoperable control.
2. Remove and discard peel-off paper to expose adhe-
sive liner.
3. Run a bead of silicone on reverse side edge of
iTempo control (silicone provided).
4. Insure the mounting surface is clean and dry as
required for good adhesion. Apply silicone into
the hole in the wall as required to create a
moisture seal. Hold the control with the LED
display in the 12 o’clock position and press the
control against the wall until the adhesive sticks
and holds firmly as shown above.
iTempo INSTALLATION
15
69992_PUR_100431_MrSteam.indd 16 2013-11-15 07:36