Controls Installation Sheet
mr
.
steam
®
  Installation & Operating Instructions
______________________________________________________________
13
Display
Up Key
Pause Key
Down Key
ON/OFF
Key
mr.steam
DIAGRAM 3
DIAGRAM 4
TIMER FEATURE 
When the control is turned ON a 60 minute time 
duration is initiated. The control will turn off 
after 60 minutes unless the control is turned off 
manually.
MEMORY FEATURE
If the control is turned off manually before 60 
minutes then the default temperature of 110˚F 
will be used the next time the control is turned 
on. If the control times out at 60 minutes (not 
manually turned off) then the previous user tem-
perature setting will be used when the steam-
bath is used again.
SETTING THE TEMPERATURE 
Diagram 3
The control is pre-set and will display the tem-
perature setting of 110˚F (default setting). Use 
the UP and DOWN keys to change the tempera-
ture setting from 80˚ F to 120˚ F in one degree 
increments.
CHANGING THE TEMPERATURE 
UNITS 
 (F˚/C˚) Diagram 4
When the generator is Off, Press and hold ON/
OFF key for 10 seconds. The temperature units 
will be displayed as Fahrenheit (TuF) or Celsius 
(TuC). Use the UP/DOWN keys to choose be-
tween (TuF) and (TuC). Press ON/OFF key to ac-
cept the new units and exit.