User Guide

Section7.Presstoolwearandfinalrejection
Overtimewithheavyuse,thepresstoolcomponents/partswillwear,affectingthePressForce.Ifthetool
cannotbeadjustedtoreachtherequiredPressForceofabout33pdf(poundforce),orthepressjawsdonot
completelycloseanymore,thepresstoolshouldbediscarded.
Thispresstoolhassuccessfullygonethrough5000testcycles.Duringthistest,allnecessaryadjustmentswere
madeonthepresstool,butwithoutreplacinganyofthepresstoolparts/components.
Section8.Careandmaintenance
A)Whenthetoolisnotinuse,itshouldbestoredineitherofthefollowingways:
Withinsertsmounted;leavetoolopen.Removethehandleextensionsandprotectthethreads.
Withinsertsremoved;closethetool.Removethehandleextensionsandprotectthethreads.
B)Thepresstoolshouldbemaintainedperiodicallybycleaningandaddinglubricationoiltopins
orscrewsatthefollowingspecifiedlocationsatleastonceeverymonth.
C)Keepinsertsclean.
D)Makesurethethreadsonhandleextensionsarekeptcleanandfreefromdamage.Ananticorrosion
agent(suchasWD40)shouldbesprayedontothethreadsperiodically.
E)Adjustmentscrewsandpinsshouldbeperiodicallytakenoff,cleanedandlubricated.
Shouldyouhaveanyquestionsregardingourpresstools,pleasefeelfreetodirectany
questionstousviaemailatinfo@mrpex systems.comorcallusat18007163406.