Install Instructions
The installaon of the MrPEX® actuators is very easy and quick. Aer removing the blue plasc
manual valve knob on the return manifold, by hand screw the plasc VA 10 adapter onto the on/o
valve. The actuator snaps on to the adapter with a slight push. The actuators are supplied parally
open to aid installaon. It is necessary to cycle the actuator completely before it will close all the
way. On start up, power the actuator and let it completely open. Blue indicator will pop up. Let it
sit for about 10 minutes. Once power is removed, the actuator will close completely, and the blue
indicator will be ush with the top. The actuators are Normally Closed type.
Connecng the actuators is the last operaon of the manifold installaon. Do not install any
actuators before pressure tesng and venng the manifold.
Refer to the actuator installaon guide to determine the power requirements and wiring instrucons.
Installaon of MrPEX Valve Actuator 24V AC
The balancing turns of the owmeter are intended starng from the closed posion.