Use and Care Manual
2
Installation Instructions and Owner’s Manual
Unvented LP-Gas Vent Free Room Heaters
This appliance may be installed in an aftermarket* permanently manufactured (mobile) home, where not prohibited 
by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not 
convertible for use with any other gas. 
*Aftermarket completion of sale, not for the purpose of resale, from the manufacturer.
WARNINGS
IMPORTANT: Read this owner’s manual carefully 
and completely before trying to assemble, operate, 
or service this heater. Improper use of this heater 
can cause serious injury or death from burns, re, 
explosion, electrical shock, and carbon monoxide 
poisoning. 
WARNING: This appliance is equipped for (natural 
or propane) gas. Field conversion is not permitted.
WARNING: Do not use any accessory not 
approved for use with this heater. 
WARNING: Any change to this heater or its 
controls can be dangerous. 
•  Do not place clothing or other ammable 
material on or near the appliance. Never place 
any objects on the heater. 
•  Due to high temperatures, heater should be 
kept out of trafc and away from furniture and 
draperies. 
•  Surface of heater becomes very hot when 
running. Keep children and adults away 
from hot surfaces to avoid burns or clothing 
ignition. Heater will remain hot for a time after 
shutdown. Allow heater surfaces to cool before 
handling. 
•  Young children should be carefully supervised 
when they are in the same room with heater. 
•  Make sure grille guard is in place before 
running heater. If screen or grille guard is 
removed for servicing it must be replaced prior 
to operating the heater. 
•  Keep the appliance area clear and free from 
combustible materials, gasoline, and other 
ammable vapors and liquids. 
CONTENTS
WARNINGS ........................................................................ 2
SPECIFICATIONS .................................................................3
PRECAUTIONS ....................................................................3
IGNITION SYSTEM BATTERY INSTALLATION .......................4 
BLOWER FAN CONTROL SWITCH OPERATION ....................4 
DETERMINING THE TYPE OF HEATER LOCATION SPACE ..... 5
INSTALLATION ...................................................................6
FASTENING HEATER TO WALL ............................................ 7
FLOOR MOUNTING AWAY FROM WALL .............................8
CONNECTING TO GAS SUPPLY ...........................................8
OPERATING YOUR HEATER ............................................... 10
CLEANING AND MAINTENANCE .......................................11
TROUBLESHOOTING ........................................................ 14
EXPLODED-VIEW PARTS DRAWING ................................... 16
PARTS LIST ....................................................................... 17
WARRANTY  .................................................................... 20
CAUTION: Never connect heater directly to the 
Propane supply. This heater requires an external 
regulator (not supplied). Install the external regula-
tor between the heater and Propane/LP supply. 
The installer must supply an external regulator. 
The external regulator will reduce the incoming 
gas pressure to between 11 and 14 inches 
of water. If you do not reduce incoming gas 
pressure heater regulator damage could occur. 
Install external regulator with the vent pointing 
down. Pointing the vent down protects it from 
freezing rain or sleet.