Specifications

© The Fulton Companies 2012
2-2
INSTALLATION VTG-IOM-2012-1001 SECTION 2
! WARNING
All information in this manual is for
reference and guidance purposes,
and does not substitute for required
professional training, conduct,
and strict adherence to applicable
jurisdictional/professional codes and
regulations.
Crystalline silica may be present
in components of this equipment.
Exposure to crystalline silica may
pose signi cant health hazards,
including but not limited to eye and
respiratory system damage. Per
the Centers for Disease Control and
Prevention (CDC) and Occupational
Safety and Health Administration
(OSHA), appropriate personal
protective equipment must be worn
to minimize exposure to hazardous
substances. Refer to most current
guidelines o ered by the CDC and
OSHA for more information, including
personal protective equipment
recommendations.
4 CAUTION
This boiler is certi ed for indoor
installation only. NEMA 3R
con guration is available as a
factory option; this boiler may not be
retro tted.
This boiler is not designed for use in
systems where water is continuously
replenished. The warranty is valid for
closed loop systems only.
Fulton cannot be held responsible
for the selection, engineering,
installation, or sizing of any
additional equipment or components
of the hydronic heating system.
Product Overview
Prior to the performance of installation, operation, or maintenance procedures,
personnel should become familiar with the equipment (Table 1) and its
components.
The Fulton Vantage hot water boiler is an automatic, fuel- red, ultra high-
e ciency boiler. The boiler can either be of the sealed combustion/direct vent
type or utilize conventional combustion air intake and ue methods.
The boiler is capable of sidewall venting when the appropriate venting materials
are used, and when permitted by local code requirements.
The Fulton Vantage boiler is certi ed to Underwriters Laboratories (UL) 795
Issue 2006/10/27 Edition 6 UL Standard for Safety Commercial-Industrial Gas
Heating Equipment. The boiler heat exchanger is manufactured and stamped
in accordance with American Society of Mechanical Engineers (ASME) Boiler
and Pressure Vessel Code, Section IV for a maximum allowable working pressure
and temperature of 160 psi and 210 F (99 C) respectively. All Vantage boilers are
hydrostatically tested, test red and shipped as a complete packaged unit.
Fuel, water and electrical connections are similar to other boilers of this type.
There are various burner and control con gurations available with the Vantage
boiler. Please be aware of which burner and control con guration has been
designed speci cally for your application.
This Vantage boiler is to be installed as part of a hydronic heating system. A
quali ed engineer must be consulted for the selection of the equipment and
components of the heating system. Various system conditions can result in
incorrect heat distribution to users of the heating system.
Each Vantage Boiler is supplied with the following:
§ Integrated combustion supervision and temperature operating control
§ Operating and high temperature probes in presure vessel
§ Low water probe in pressure vessel
§ ASME safety relief valve
§ Installation and Operation Manual
§ Test re report
§ Separate wiring diagram
§ Combustion Air Adapter
§ Temperature and pressure (T&P) gauge
§ 2” drain valve
§ 1 can touch up paint
§ Reducing bushing for safety relief valve