1. Battery Voltage Alarm & Shutdown
Battery Voltage Alarm & ShutdownBattery Voltage Alarm & Shutdown
Battery Voltage Alarm & Shutdown
Battery Voltage.
Battery Low Alarm Battery Low Shutdown DC range
12V 10.8V 10.3V 10.5V~14.5Vdc
24V 21.5V 20.0V 20V~29.3Vdc
48V 42.5V ~ 43.0V 40.0V 40V~58.5Vdc
2. High Temperature FAULT alarm
2. High Temperature FAULT alarm2. High Temperature FAULT alarm
2. High Temperature FAULT alarm
System Internal temperature 60°C
Heat Sink temperature 80°C
3. Inverter Inrush Current:
3. Inverter Inrush Current:3. Inverter Inrush Current:
3. Inverter Inrush Current:
Model Name Inrush Current (220Vac, 5 cycles) Inrush Current = KVA
812LC 9.5A 2.1KVA
1624LC 19A 4.2KVA
2424LC 24.5A 5.4KVA
4024LC 33A 7.2KVA
6048LC 72A 15.8KVA
8048LC 84A 18.5KVA
**Maximum surge is purposely lowered for operational safety and stability.
4
44
4. System Current Consumption (with & without Optional Green Power Mode
. System Current Consumption (with & without Optional Green Power Mode. System Current Consumption (with & without Optional Green Power Mode
. System Current Consumption (with & without Optional Green Power Mode)
))
)
Note: this feature will activate when load is <~20w. Values below are approximate based on average.
Without Green Power Mode With Green Power Mode
812LC 3.6A (reference) < 0.63 A
1624LC 2.6A (reference) < 0.42A
2424LC 3.2A (reference) < 0.42A
4024LC 3.8A (reference) < 0.63A
6048LC 2.7A (reference) < 0.42A
8048LC 3.8A (reference) < 0.42A
5
55
5.
. .
. Circuit Breaker Rating (Based on 220v)
Circuit Breaker Rating (Based on 220v)Circuit Breaker Rating (Based on 220v)
Circuit Breaker Rating (Based on 220v)
812LC 8A
1624LC 8A
2424LC 20A
4024LC 30A
6048LC 40A
8048LC 40A