RECEIVE AND TRANSMIT
Filter setting
When an optional lter is installed, set the optional l-
ters in initial set mode. Optional filters are not se-
lected by default. (p. 47)
D Optional lter setting
q While pushing and holding [SET], push [POWER]
to enter initial set mode.
w Push [UP Y] or [Z DN] one or more times until
FIL appears on the display.
e Rotate the tuning dial to select the installed lter.
•“no, 52A, 53A, 96, 222 and 257 indicate no op-
tional filter, FL-52A, FL-53A, FL-96, FL-222 and
FL-257, indicate respectively for 455 kHz IF filter se-
lection.
r Push [PWR] to exit initial set mode.
D Expanded lter selection
The selectable lter combinations can be expanded
by setting the expanded lter selection to ON. Then
extra wide or narrow lter can be selected on desired
mode.
q While pushing and holding [SET], push [PWR] to
enter initial set mode.
w Push [UP Y] or [Z DN] one or more times until
EXP FIL appears.
e Rotate the tuning dial to turn the expanded filter
selection on.
If onis selected, the expanded lter selection can be
used.
Wide/narrow lter selecting
r Push [UP Y] one or more times
until WIDE ✻✻ or NAR ✻✻ ap-
pears on the display.
t Push [MODE] one or more times
to select the desired mode.
y Rotate the tuning dial to select a
lter.
u Repeat steps t and y to select
IF filters for other modes, if de-
sired.
The filter combinations are stored
depending on operating modes.
i Push [POWER] to exit initial set
mode.
no FL-52A FL-53A FL-96 FL-222 FL-257
SSB
no no
222 (1.8 K)
52A (500) 53A (250)
CW
52A (500) 53A (250) 222 (1.8 K)
RTTY
52A (500) 53A (250) 222 (1.8 K)
AM
NOR (2.4 K)
52A (500)
53A (250)
96 (2.8 K) 222 (1.8 K) 257 (3.3 K)
NOR (2.4 K)
NOR (2.4 K)
NOR (2.4 K)
NOR (2.4 K)
NOR (2.4 K)
: default
no FL-52A FL-53A FL-96 FL-222 FL-257
SSB
no no no 96 (2.8 K) no 257(3.3 k)
THU (6 K) THU (6 K) THU (6 K) THU (6 K) THU (6 K) THU (6 K)
CW
no no no 96 (2.8 K) no
257(3.3 k)
THU (6 K) THU (6 K) THU (6 K) THU (6 K) THU (6 K) THU (6 K)
RTTY
no no no 96 (2.8 K) no
257(3.3 k)
THU (6 K) THU (6 K) THU (6 K) THU (6 K) THU (6 K) THU (6 K)
AM
–– –– –– –– ––
: default
Narrow lter setting table
Wide lter setting table
Optional lter selection
Expanded lter selection on
Wide lter setting
Narrow lter setting
IC-718.qxd 02.9.6 14:29 Page 25