Appendix 2 DVQ-2, DMR 4 RT Pin Confi guration
EXTERNAL DEVICES
Connecting External Alarms devices - example using a Siren: Use pins 7,
8 inputs and 15 COM when connecting external alarms like sirens, or horns.
NO (Normally Open):
Under standby mode the DVR COM pin 8 is disconnected with the normally
open (NO) device. When a DVR is triggered by an alarm trigger or motion
detection, the COM (on the DVR) connects with (NO) normally open device
and siren (external device) will start sounding and fl ashing.
NC (Normally Closed):
Under standby mode the DVR COM pin 7 is connected with the normally
closed (NC) device. When a DVR is triggered by an alarm trigger or motion detection, the COM (on the DVR) disconnects
with (NC) normally closed device and siren (external device) will start sounding and fl ashing.
INPUT ALARMS
Connecting Input Alarm devices - example using a Magnetic Contacts: Use pins 3, 6 inputs and 9 Signal Ground
when connecting Input Alarms like magnetic contacts.
Alarm is set for LOW):
Under standby mode the DVR pin 3 to 6 are 5v TTL high, when external input device (Magnetic Contacts) input is
activated or is low or grounded (zero), this will zero pins 3 ~ 6 and the DVR will start recording and buzzer will sound.
Alarm is set for HIGH):
Under standby mode the DVR pin 3 to 6 are 0v TTL low, when external input device (Magnetic Contacts) input is activated
or is high (5v TTL), this will raise the voltage to 5V TTL to pins 3 ~ 6 and the DVR will start recording and buzzer will
sound.
PIN DESCRIPTION
PIN NUMBERS:
1 RS232-TX DVR pin is used to serially communicate with remote PC using the RS-232 PROTOCOL. Use
SERIAL PROTOCOL table for command set.
2 RS232-RX DVR pin is used to serially communicate with remote PC using the RS-232 PROTOCOL. Use
SERIAL PROTOCOL table for command set.
3 ~ 6 ALARM INPUT
Use ALARM INPUT ( PINS 3 -- 6 ) and GND ( PIN 9 ) to activate the DVR to start recording and trigger internal
buzzer sound.
7 EXTERNAL ALARM NC Under the normal operation, COM connects with NC and disconnects from NO. But when any
alarm is triggered, COM disconnects with NC and connects with NO.
NOTE: MAXIMUM voltage allowable is 24DCV 1A.
8 EXTERNAL ALARM NO. Under the normal operation, COM disconnects with NO. But when any alarm is triggered,
COM connects with NO.
NOTE: MAXIMUM voltage allowable is 24DCV 1A.
68