Technical Specifications
TECHNICAL DATA
Physical Properties: Blended synthetic fibers and polyethylene film.
Inert hot-melt adhesive.
Weight ..............................12 lbs/roll • 17.28 oz/sq yd • 1.92 oz/sq ft
Thickness ................................................................................0.125"
Density ..........................................................................11.52 lbs / ft
3
Compression Resistance @ 25% ............................................. 9.5 psi
Compression Resistance @ 30% ........................................... 16.6 psi
Compression Resistance @ 50% ........................................... 85.5 psi
Breaking Strength ............................. Length 72.1 lbs; Width 100 lbs
Compression Set @ 25% ......................................................... 18.8%
R-Value (@0.125”) ............................0.58 hr-ft
2
-degF/Btu (4.64/ inch)
Flammability Meets or exceeds Federal Flammability Standard: 1-70
(Pill Test) and ASTM E84 Steiner Tunnel Test.
Volatile Organic Compounds (VOC) Tested for 81 different off-gas
compounds in accordance with CA 01350. Passed to the level of
Collaborative for High Performance Schools (CHPS) and Office Spaces.
Product Emissions Passed the most rigorous emissions test: Section
01350 for CHPS and Standard Office 8mm Laminate.
SOUND PROPERTIES
IMPACT SOUND TRANSMISSION
The method is designed to measure the impact sound transmission
performance of a floor-ceiling assembly in a controlled laboratory
environment.
IIC Flooring Sub-oor
71 Laminate WITH ceiling assembly
57 Floating Engineered Wood WITH ceiling assembly
68 Laminate WITH suspended gypsum board assembly
60 (Field IIC) Laminate NO ceiling assembly
59 Engineered Wood
Fire Rated System - UL L521 Wood frame with
3/4” gypsum concrete
61 Floating Engineered Hardwood Wood frame, gypsum concrete, isolation clips
59 Floating Engineered Hardwood Wood frame and gypsum concrete
SOUND TRANSMISSION LOSS
The sound-insulating property of a partition element is expressed in
terms of the sound transmission loss.
STC Flooring Sub-oor
66 Floating Engineered Wood WITH suspended gypsum board assembly
54 Laminate NO ceiling assembly
52 Laminate Wood frame and gypsum concrete
61 Engineered Wood
Fire Rated System - UL L521 Wood frame with
3/4” gypsum concrete
59 Floating Engineered Hardwood Wood frame, gypsum concrete, isolation clips
61 Floating Engineered Hardwood Wood frame and gypsum concrete
DELTA TEST
Tests the impact insulation difference between a bare concrete subfloor
with no flooring materials and the same concrete subfloor with flooring
and underlayment.
Delta IIC Flooring
22 QuietWalk Plus under Laminate
Moisture Absoption Properties
Moisture Absorption Approx. 650% by weight
Moisture Statement. QuietWalk Plus will absorb and allow dispersion throughout the
product of water moisture in accumulations not exceeding one gallon per 24 hrs per 300
square feet of product and/or allowed to continue to accumulate for more than 7 days.
Actual in-house tests have shown results up to 5 times that amount.