User's Manual
NPort W2150A/W2250A Series  Web Console: Serial Port Settings 
8-15 
Connection control 
Default  Startup/None 
Options  Startup/None, Any Character/None, Any Character/Inactivity Time, DSR On/DSR Off, DSR 
On/None, DCD On/DCD Off, DCD On/None 
Description  This field specifies how connections to the device are established and closed.  
Startup/None: The connection will be opened as the NPort starts up. The connection will 
only be closed manually. 
Any Character/None: The connection will be opened as soon as a character is received 
from the attached device. The connection will only be closed manually.  
Any Character/Inactivity Time: The connection will be opened as soon as a character is 
received from the attached device. The connection will be closed if no data is received for 
the time specified in Inactivity time. 
DSR On/DSR Off: The TCP connection is opened when the DSR signal is on, and closed 
when the DSR signal is off. 
DSR On/None: The TCP connection is opened when the DSR signal is on. The connection 
will only be closed manually.  
DCD On/DCD Off: The TCP connection is opened when the DCD signal is on, and closed 
when the DCD signal is off. 
DCD On/None: The TCP connection is opened when the DCD signal is on. The connection 
will only be closed manually. 
Packet length 
Default  0
Options  0 to 1024 
Description  This field specifies the maximum amount of data that is allowed to accumulate in the serial 
port buffer before sending.  
0: Packet length is disregarded and data in the buffer will be sent as specified by the 
delimiter settings or when the buffer is full.  
1 to 1024: Data in the buffer will be sent as soon it reaches the specified length. 
Delimiter 1 and 2 
Default  Disabled 
Options  Disabled, Enabled, 00 to FF 
Description  These fields are used to define special delimiter character(s) for data packing. Enable 
Delimiter 1 to control data packing with a single character; enable both Delimiter 1 and 2 
to control data packing with two characters received in sequence. 
When these fields are enabled, serial data will accumulate in the serial port’s buffer until 
the buffer is full or until the specified delimiter character(s) are received. For example, the 
carriage-return character could be used as a delimiter in order to transmit each sentence 
or paragraph in a separate packet. Data will be packed according to Delimiter process.  
Delimiters must be incorporated into the data stream at the software or device level. 
ATTENTION 