NPort W2250/2150 Plus User’s Manual  Web Console Configuration 
 5-19
UDP Mode 
Data Packing 
Delimiter 1/2 
Setting  Factory Default  Necessity 
00 to FF (hex)  None  Optional 
Once the NPort W2250/2150 receives both delimiters through its serial port, it immediately packs 
all data currently in its buffer and sends it to the NPort W2250/2150’s Ethernet port. 
ATTENTION 
  Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips clearing of the buffer. If the size 
of the serial data received is greater than 1 KB, the NPort W2250/2150 will automatically pack 
the data and send it to the Ethernet. However, to use the delimiter function, you must at least 
enable Delimiter 1. If Delimiter 1 is left blank and Delimiter 2 is enabled, the delimiter function 
will not work properly. 
Force transmit 
Setting  Factory Default  Necessity 
0 to 65535 ms  0  Optional 
0: Disable force transmit timeout. 
1 to 65535: Forces the NPort W2250/2150’s TCP/IP protocol software to try to pack serial data 
received during the specified time into the same data frame. 