Alarm
System Alarm
In addition to the LED indicators, two kinds of system alarm are provided by the VPort 25 for
notifying the system operation administrator.
Alarm Type Triggered Condition Triggered Action
Case Open Alarm
The upper case is opened
Email and Relay Output
(DO)
Network Disconnected
Network disconnected Relay Output (DO)
Case Open Alarm
Setting Description Default
Enable Case Open Alarm Enable/ Disable the alarm of open case
sensor
Disable
Trigger Relay 1 Alarm Enable or disable the action of triggering
Relay Output (DO) alarms.
Disable
Auto warning via
recipient email
Send a warning Email to the recipient
email address being setup in SMTP server
Disable
Network Disconnected Alarm
Setting Description Default
Enable network
disconnected alarm
Enable or disable network disconnected
alarm.
Disable
Trigger Relay alarm
Enable or disable the action of triggering
Relay Output (DO) alarms.
Disable
NOTE
Since several alarms can be set up to trigger the VPort’s relays, the administrator should
configure these alarms carefully in case a relay message is read incorrectly.