User`s manual
Moxa VPort 16-M12 Technical Specifications
D-2
Power Requirements
Input:
Power-over-Ethernet (IEEE 802.3af)
Power Consumption:
6.5 W
Physical Characteristics
Housing:
Metal and glass, optional PC dome cover, IP66-rated
Dehumidifying Membrane:
GORE protective vent
Dimensions:
• Standard model: 125 x 125 x 109.1 mm (5.6
x 5.6 x 4.3 in)
• Dome model: 125 x 125 x 120.7 mm (5.6 x 5.6 x 4.8 in)
Installation:
Surface (ceiling) or flush (recessed) mounting
Security
Password:
User level password protection
Filtering:
By IP address
Alarms
Intelligent Vi
deo: Tamper alarm
Video Motion Detection:
Includes sensitivity tuning
Video Loss:
Video loss alarm
Scheduling:
Daily repeat timing schedule
Imaging:
JPEG snapshots for pre/trigger/post alarm images
Custom Alarms:
HTTP event servers for setting customized alarm actions
Pre
-alarm Buffer: 9 MB video buffer for JPEG snapshot images
Local Video Recording:
Triggered by the alarm within the given time period
Environmental Limits
Operating Temperature:
-25 to 55°C (-13 to 131°F)
Storage Temperature:
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity:
5 to 95% (non-condensing)
Conformal Coating:
Available on request
Standards and Certifications
Safety:
UL 60950-1
EMI:
FCC Part 15 Subpart B Class A, EN 55022 Class A
EMS:
EN 61000
-4-2 (ESD), Level 3,
EN 61000
-4-3 (RS), Level 3,
EN 61000
-4-4 (EFT), Level 3,
EN 61000
-4-5 (Surge), Level 3,
EN 61000
-4-6 (CS), Level 3,
EN 61000
-4-8,
EN 61000
-4-11
Rolling Stock:
EN 50155:2007 compliance (shock, vibration, temperature, EMC)
Shock:
IEC 61373
Freefall:
IEC 60068-2-32
Vibration:
IEC 61373
Vandal resistance:
EN 62262, IK10 level (dome cover model)
Note: Please check Moxa's website for the most up
-to-date certification status.
Warranty
Warranty Period:
3 years
Details:
See www.moxa.com/warranty
Minimum Viewing System Requirements
CPU:
Pentium 4, 2.4 GHz
Memory:
512 MB of memory
OS:
Windows XP/2000 with SP4 or above
Browser:
Internet Explorer 6.x or above
Multimedia:
DirectX 9.0c or above