User`s manual
TN-5516/5518 Series Featured Functions
3-74
Syslog Server 1
Setting Description Factory Default
IP Address Enter the IP address of 1st Syslog server used by your network. None
Port Destination (1 to
65535)
Enter the UDP port of 1st Syslog server. 514
Syslog Server 2
Setting Description Factory Default
IP Address Enter the IP address of 2nd Syslog server used by your
network.
None
Port Destination (1 to
65535)
Enter the UDP port of 2nd Syslog server. 514
Syslog Server 3
Setting Description Factory Default
IP Address Enter the IP address of 3rd Syslog server used by your network. None
Port Destination (1 to
65535)
Enter the UDP port of 3rd Syslog server. 514
NOTE The following events will be recorded into the TN-5500’s Event Log table, and will then be sent to the specified
Syslog Server:
• Cold start
• Warm start
• Configuration change activated
• Power 1/2 transition (Off ( On), Power 1/2 transition (On ( Off)
• Authentication fail
• Topology changed
• Master setting is mismatched
• Port traffic overload
• dot1x Auth Fail
• Port link off / on
Using HTTPS/SSL
To secure your HTTP access, the TN-5500 supports HTTPS/SSL to encrypt all HTTP traffic. Perform the following
steps to access the TN-5500’s web browser interface via HTTPS/SSL.
1. Open Internet Explorer and type https://TN-5500’s IP address in the address field. Press Enter to
establish the connection.
2. Warning messages will pop out to warn the user that the security certificate was issued by a company they
have not chosen to trust.