Installation Guide
Table Of Contents
- 8 -
RX Sensitivity
TCF-142-S series: -25 dBm
TCF-142-M series: -20 dBm
Point-to-Point
Transmission
Half or Full duplex
Ring Transmission
Half duplex
Environmental Limits
Operating Temperature
0 to 60°C (32 to 140°F), 5 to 95 % RH
Extended Operating
Temperature (T models)
-40 to 75°C (-40 to 167°F)
Storage Temperature
-40 to 75
°
C (-40 to 167
°
F), 5 to 95 % RH
Power
Input Power Voltage
12 to 48 VDC
Power Line Protection
1 kV Burst (EFT), EN61000-4-4
1 kV Surge, EN61000-4-5
Reverse Power Protection
Protects against V+/V- reversal
Over Current Protection
Protects against 2 signals shorted together:
1.1A
Power Consumption
140 mA at 12 VDC
67.7 mA at 24 VDC
28.7 mA at 48 VDC
Physical Characteristics
Dimensions
67 x 100 x 22 mm
90 x 100 x 22 mm (including ears)
Material
Aluminum (1 mm)
Gross Weight
320 g
Regulatory Approvals
EMC
CE, FCC (Class A)
LVD
EN 60950-1
Safety
UL 60950-1
EMI
FCC Part 15 Subpart B Class B, EN 55032
Class B
EMS
EN61000-4-2 (ESD), Criteria B, Level 2
EN61000-4-3 (RS), Criteria B, Level 2
EN61000-4-4 (EFT), Criteria B, Level 2
EN61000-4-5 (Surge), Criteria B, Level 2
EN61000-4-6 (CS), Criteria B, Level 2