User Manual

- 16 -
Wiring the SPL-24’s Power Outputs
The two left-most contacts of the 3-contact terminal block connector on
the SPL-24’s top panel are used for 24 VDC output. Top and front views of
one of the terminal block connectors are shown here.
STEP 1:
Insert the negative/positive DC
wires into the V-
/V+
terminals.
STEP 2:
To keep the DC wires from pulling loose, use a small
flat
-blade screwdriver to tighten the wire-clamp
screws on the front of the terminal block connector.
STEP 3:
Insert the plastic terminal block connector prongs
into the terminal block receptor, which is located on
SPL
-24's top panel.
Patent http://www.moxa.com/doc/operations/Moxa_Patent_Marking.pdf