LED Indicators
LED Name LED Color/Status LED Function
Ready
Green Power is on and functioning normally
On 1 sec Off 1 sec Resetting to default
On 5 sec
Off 5 sec.
IHS pre-heating
Off Power error, or off
RAID
Red RAID recovery fails
On 1 sec Off 0.5 sec RAID disk is recovering
On 5 sec Off 1 sec HDD1 fails
On 10 sec Off 1 sec HDD 2 fails
On 15 sec Off 1 sec HDD 1 and HDD2 fail
On 1 sec Off 5 sec HDD overheated; no power
Off RAID recovery complete, or no activity
LAN (1, 2)
Green 100 Mbps Ethernet mode
Yellow 1000 Mbps Ethernet mode
Off No Ethernet activity
HDD1
Yellow Drive 1 is writing/reading data
Off No activity
HDD2
Yellow HDD2 is writing/reading data
Off No activity
Real Time Clock
The embedded computer’s real-time clock is powered by a lithium battery. We strongly recommend that you
NOT replace the lithium battery on your own. If the battery needs to be changed, contact the Moxa RMA service
team at http://www.moxa.com/rma/about_rma.aspx
.
WARNING
There is a risk of explosion if the wrong type of battery is used. To avoid this potential danger, always be sure
to use the correct type of battery. Contact the Moxa RMA service team if you need to replace your battery.