User`s manual
PT-7828 User’s Manual Featured Functions
3-13
Clock Stratum The stratum number describes one measure of
the quality of a clock. Each clock is
characterized by a stratum number used by the
best master clock algorithm as one parameter of
clock quality.
4
Clock Identifier Properties of the clock. DFLT
PTP Port Settings
Setting Description Factory Default
Port Enable Enable or disable PTP port operation. None
Port Status Display PTP port real status. PTP_DISABLED
System File Update—By Remote TFTP
The PT-7828 supports saving your configuration or log file to a remote TFTP server or local host.
Other PT-7828 switches can also load the configuration at a later time. The PT-7828 also supports
loading firmware or configuration files from the TFTP server or a local host.
TFTP Server IP/Name
Setting Description Factory Default
IP address of TFTP
server
This specifies the IP address or name of the remote
TFTP server. This must be specified before
downloading or uploading files.
None
Configuration Files Path and Name
Setting Description Factory Default
Max. 40 characters This specifies the path and file name of the
PT-7828’s configuration file on the TFTP server.
None
Firmware Files Path and Name
Setting Description Factory Default
Max. 40 characters This specifies the path and file name of the
PT-7828’s firmware file.
None
Log Files Path and Name
Setting Description Factory Default
Max. 40 characters This specifies the path and file name of the
PT-7828’s log file.
None