Datasheet
www.moxa.com
3
Power Parameters
Input Current 0.8 A (max.)
Input Voltage 9 to 36 VDC
Power Consumption 5 W (typ.)
Power Connector Terminal block
Reverse Polarity Protection Supported
Power Button Reset button
Physical Characteristics
Housing Metal
IP Rating IP30
Dimensions 128.5 x 26 x 89.1 mm (5.06 x 1.02 x 3.51 in)
Weight 550 g (1.22 lb)
Installation DIN-rail mounting, Wall mounting (with optional kit)
Environmental Limits
Operating Temperature Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -30 to 70°C (-22 to 158°F)
1
Storage Temperature (package included) -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Standards and Certifications
EMC EN 55032/24, EN 61000-6-2/-6-4
EMI CISPR 22, FCC Part 15B Class A
EMS IEC 61000-4-6 CS: 10 V; 150 kHz to 80 MHz
IEC 61000-4-8: 30 A/m
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV
Freefall IEC 60068-2-32
Hazardous Locations ATEX, IECEx, Class I Division 2
Radio Frequency FCC, PTCRB
Cellular Standards EN 301489-1/17
EN 301511
EN 301908-1
AS/CA S042
EN 62311(MPE SAR)
Safety UL 60950-1, UL 62368-1
Shock IEC 60068-2-27
Vibration IEC 60068-2-6
1. When continuously operating in temperatures below -25° C (-13° F), the device may experience a very brief loss of cellular connectivity. The device will
automatically attempt to reconnect and should have no impact on performance.