Datasheet
www.moxa.com
3
Stop Bits 1, 1.5, 2
Parity None, Even, Odd, Space, Mark
Flow Control None, RTS/CTS, XON/XOFF
RS-485 Data Direction Control ADDC® (automatic data direction control)
Pull High/Low Resistor for RS-485 1 kilo-ohm, 150 kilo-ohms
Terminator for RS-485 120 ohms
Surge 1 kV
Physical Characteristics
Housing Metal
Installation Desktop, DIN-rail mounting (with optional kit), Wall mounting
Dimensions (with ears, without antenna) 77 x 111 x 26 mm (3.03 x 4.37 x 1.02 in)
Dimensions (without ears or antenna) 100 x 111 x 26 mm (3.94 x 4.37 x 1.02 in)
Weight NPort W2150A/W2150A-T: 547 g (1.21 lb)
NPort W2250A/W2250A-T: 557 g (1.23 lb)
Antenna Length 109.79 mm (4.32 in)
Environmental Limits
Operating Temperature Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature (package included) -40 to 75°C (-40 to 167°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Power Parameters
Input Current NPort W2150A/W2150A-T: 179 mA @ 12 VDC
NPort W2250A/W2250A-T: 200 mA @ 12 VDC
Input Voltage 12 to 48 VDC
Standards and Certifications
EMC EN 55032/24
EMI CISPR 32, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
IEC 61000-4-11
Radio Frequency CE (ETSI EN 301 893, ETSI EN 300 328, ETSI EN 301 489-17, ETSI EN 301 489-1), ARIB
RCR STD-33, ARIB STD-66
Reliability
Alert Tools RTC (real-time clock)
Automatic Reboot Trigger Built-in WDT