User Manual

- 7 -
4. Standards Covered:
EN 60079-0:2012+A11:2013, IEC 60079-0 Ed 6.0,
EN 60079-15:2010, IEC 60079-15 Ed 4.0
5. The conditions of safe usage:
The Ethernet Communications Devices are intended for
mounting in a tool-accessible ATEX-Certified or IECEx-Certified
(for models with the suffix -CT or -IEX) IP54 enclosure and
used in an area of not more than pollution degree 2 as defined
by IEC/EN 60664-1 or IEC 60664-1 (for models with the suffix -
CT or -IEX).
Conductors suitable for use in an ambient temperature greater
than 91°C must be used for the power supply terminal.
A 4 mm
2
conductor must be used when connection to the
external grounding screw is utilized.
Provisions shall be made, either in the equipment or external to
the equipment, to prevent the peak rated voltage being
exceeded by the transient disturbances of more than 140%.
6. Terminal block information.
Input Terminal Block (J1)Dinkle Enterprise Co, Ltd, Cat. No.
5EHDR-08P, rated 300V, 10A, 105, suitable for 28-12 AWG
(0.12-3.31 mm²) wire size, torque value 4.5 lb-in (0.508 N-m).
Terminal blocks do not accommodate more than one individual
conductor per clamping point. Mechanically secured by two
screws.
Signal Channel Terminal Block (J2, for the NPort IA5150A
Series only)Dinkle Enterprise Co, Ltd, Cat. No. 5EHDR-05P,
rated 300V, 10A, 105, mating with Cat. No. 5ESDV-05P,
rated 300V, 10A, 105, suitable for 28-12 AWG (0.12-
3.31mm²) wire size, torque value 4.5 lb-in (0.508 N-m).
Terminal blocks do not accommodate more than one individual
conductor per clamping point. Mechanically secured by two
screws.
7. Address: Moxa Inc, 4th Fl, No.135, Lane 235, Baoqiao Road,
Xindian District, New Taipei City, 231 Taiwan
Pull-high, Pull-low, and Terminator for RS-485
Remove the NPort IA5000A’s top cover and you will find DIP switches
to adjust each serial port’s pull-high, pull-low, and terminator.
NPort IA5150A Series
NPort IA5250A Series