RS-422/2W RS-485/4W RS-485 (Terminal Block) Pinouts
PIN
RS-485
(2W)
RS-422/
RS-485 (4W)
1
TxD+(B)
2
TxD-(A)
3
Data+(B)
RxD+(B)
4
Data-(A)
RxD-(A)
5
GND
GND
Four cables are available as optional accessories that can be used to
connect the NPort IA5000A Series to RS-232 serial devices. For your
convenience, we show precise cable wiring diagrams for each of the two
cables.
Female DB9 to Male DB9
Female DB9 to Male DB25
ATEX and IECEx Information
1. DEMKO Certification number: 12 ATEX 1014487X
IEC Certification Number: IECEx UL 13.0024X (only for models with
suffix CT or IEX)
2. Ambient Temperature Range (-40°C Tamb 75°C)
3. Certification String: Ex nA nC IIC T3 Gc