User Manual
- 3 - 
Hardware Introduction 
Demonstrated 8 port model to be an example. 
Reset Button 
Press the Reset button continuously for 5 second to load factory defaults: 
Use a pointed object to press the reset button. Release the button after 
the Ready LED stops blinking. 
RS-485 adjustable pull up/down resistor (150/1 KΩ) 
The NPort 6650 has 3 DIP Switches associated with each serial port for 
configuring the pull up/down resistors for RS-485 applications. The 
switches are located in a recess on the bottom of the NPort 6650. To 
access the switches, first remove the panel covering the recess. 
SW 
1 
2 
3 
Pull Up 
Pull Down 
Terminator 
ON 
1 KΩ 
1 KΩ 
120 Ω 
OFF 
150 KΩ 
150 KΩ 
– 
NOTE 
For RS-232 applications, all DIP Switches for the port should be 
set to the OFF position. 