Datasheet

www.moxa.com
3
Parity None, Even, Odd, Space, Mark
Flow Control RTS/CTS, DTR/DSR, XON/XOFF
Pull High/Low Resistor for RS-485 1 kilo-ohm, 150 kilo-ohms
Terminator for RS-485 120 ohms
RS-485 Data Direction Control ADDC® (automatic data direction control)
Isolation -I models: 2 kV
Surge 0.5 kV
Console Port RS-232 (TxD, RxD, GND), 3-pin (19200, n, 8, 1)
Serial Signals
RS-232 TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422 Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w Data+, Data-, GND
Power Parameters
Input Current NPort 5610-8-DT/NPort 5610-8-DT-J/NPort 5610-8-DT-T: 611 mA @ 12 VDC
NPort 5650-8-DT/NPort 5650-8-DT-J/NPort 5650-8-DT-T: 615 mA @ 12 VDC
NPort 5650I-8-DT/NPort 5650I-8-DT-T: 1066 mA @ 12 VDC
No. of Power Inputs 2
Input Voltage 12 to 48 VDC
Reverse Polarity Protection Supported
Reliability
Automatic Reboot Trigger Built-in WDT
Alert Tools Built-in buzzer and RTC (real-time clock)
Physical Characteristics
Housing Metal
Metal
Dimensions (with ears) 229 x 46 x 125 mm (9.01 x 1.81 x 4.92 in)
Dimensions (without ears) 197 x 44 x 125 mm (7.76 x 1.73 x 4.92 in)
Dimensions (with DIN-rail kit on bottom panel) 197 x 53 x 125 mm (7.76 x 2.09 x 4.92 in)
Weight NPort 5610-8-DT: 1,570 g (3.46 lb)
NPort 5610-8-DT-J: 1,520 g (3.35 lb)
NPort 5610-8-DT-T: 1,320 g (2.91 lb)
NPort 5650-8-DT: 1,590 g (3.51 lb)
NPort 5650-8-DT-J: 1,540 g (3.40 lb)
NPort 5650-8-DT-T: 1,340 g (2.95 lb)
NPort 5650I-8-DT: 1,660 g (3.66 lb)
NPort 5650I-8-DT-T: 1,410 g (3.11 lb)
Installation Desktop, DIN-rail mounting (with optional kit), Wall mounting (with optional kit)
Interactive Interface LCD panel display
Push buttons for configuration