Datasheet
www.moxa.com
3
RS-485-4w Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w Data+, Data-, GND
Power Parameters
Input Current NPort 5410/5450/5450-T: 350 mA @ 12 VDC
NPort 5430: 320 mA @ 12 VDC
NPort 5430I: 530 mA @ 12 VDC
NPort 5450I/5450I-T: 554 mA @ 12 VDC
Input Voltage 12 to 48 VDC
No. of Power Inputs 2
Power Connector 1 removable 3-contact terminal block(s)
Power input jack
Reliability
Automatic Reboot Trigger Built-in WDT
Alert Tools Built-in buzzer and RTC (real-time clock)
Physical Characteristics
Housing Metal
Dimensions (with ears) 181 x 103 x 33 mm (7.14 x 4.06 x 1.30 in)
Dimensions (without ears) 158 x 103 x 33 mm (6.22 x 4.06 x 1.30 in)
Weight 740 g (1.63 lb)
Interactive Interface LCD panel display (standard temp. models only)
Push buttons for configuration (standard temp. models only)
Installation Desktop, DIN-rail mounting (with optional kit), Wall mounting
Environmental Limits
Operating Temperature Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature (package included) -40 to 75°C (-40 to 167°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Standards and Certifications
EMC EN 55032/24
EMI CISPR 32, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
IEC 61000-4-5 Surge: Power: 1 kV; Signal: 1 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
IEC 61000-4-11 DIPs
Maritime DNV-GL (standard temp. models only)
Medical EN 60601-1-2 Class B, EN 55011 (NPort 5410/5450/5450I only)
Safety UL 60950-1