User Manual
- 3 - 
Reset Button—Press and hold the Reset button for 5 seconds to load 
factory defaults: Use a pointed object, such as a straightened paper clip 
or toothpick, to depress the reset button. This will cause the Ready LED to 
blink on and off. The factory defaults will be loaded once the Ready LED 
stops blinking (after about 5 seconds). At this point, release the reset 
button. 
LED Indicators—NPort 5200A’s top panel has four LED indicators, which 
are described in the following table. 
LED 
Name 
LED 
Color 
LED Function 
Ready 
Red 
Steady on: 
Power is on and the NPort is booting up. 
Blinking: 
Indicates an IP conflict, or DHCP or BOOTP 
server is not responding properly. 
Green 
Steady on: 
Power is on and the NPort is functioning 
normally. 
Blinking: 
The NPort has been located by the NPort 
Administrator’s Location function. 
Off 
Power is off, or a power error.. 
Link 
Orange 
10 Mbps Ethernet connection. 
Green 
100 Mbps Ethernet connection. 
Off 
Ethernet cable is disconnected. 
P1, P2
Orange 
Serial port is receiving data. 
Green 
Serial port is transmitting data. 
Off 
No data is being transmitted or received through the 
serial port. 
Adjustable pull high/low resistor and terminator for RS-422/485 
Remove the NPort 5230A/5250A’s top 
cover and you will find DIP switches to 
adjust each serial port’s pull
-high, 
pull
-low, and terminator. Do not use th
e 1 
K
Ω setting with RS-
232 mode, as doing so 
will degrade the RS
-232 signals and 
shorten the communications range.
SW 
1 
2 
3 
Pull-high resistor 
Pull-high resistor 
Terminator 
ON 
1 KΩ 
1 KΩ 
120 Ω 
OFF 
*150 KΩ 
*150 KΩ 
*– 
*Default 