Installation Guide
Table Of Contents
- MDS-G4000/MDS-G4000-L3 Series Quick Installation Guide
- Package Checklist
- Default Settings
- Panel Layouts
- Dimensions
- Ethernet Modules (Hardware Rev.2.0.0 and above)
- Power Modules (Hardware Rev.2.1.0 and above)
- DIN-rail Dimensions and Instructions
- Wall-mounting Dimensions and Instructions (Optional: WK-112-01)
- Rack-mounting Dimensions and Instructions (Optional: RK-3U-02)
- Matters That Require Attention
- Connecting the Power Inputs
- Power Terminal Blocks
- PoE Power Terminal Blocks
- Wiring the Relay Contact
- Digital Input/Output
- Installing and Removing the Ethernet Modules
- Installing and Removing the Power Modules
- Grounding the Moxa Industrial DIN-rail Switch
- RS-232 with RJ45 Interface Console Connection
- USB Connection
- Reset to Factory Default Settings
- LED Indicators
- Specifications
- Supported SFP Modules
- Restricted Access Locations
- Special Conditions of Use
- Hazardous Location Usage Terms
- 7 -
ATTENTION
Safety First
!
Be sure to
disconnect the power cord before installing and/or
wiring your Ethernet Switch. Calculate the maximum possible
current in each power wire and common wire. Observe all
electrical codes dictating the maximum current allowable for
each wire size. If the current goes above the maximum ratings,
the wiring could overheat,
which can cause serious damage to
your equipment.
Connecting the Power Inputs
The MDS-G4000 and MDS-G4000-L3 Series support 4 types of power
supply:
• PWR-HV-P48: one 110/220 VAC/VDC (90 to 264 VAC, 88 to 300
VDC), one 48 VDC PoE power input for PoE+ ports.
• PWR-LV-P48: one 24/48 VDC (18 to 72 VDC), one 48 VDC PoE
power input for PoE+ ports.
NOTE
The required power module depends on the choice of LM
-
7000H
module. Refer to the following
power/module combination
requirements.
•
LM-7000H non-PoE modules:
Any power module
•
LM-7000H PoE modules:
PWR-HV-P48, PWR-LV-P48 only
NOTE
The PWR
-LV-P48 power module is certified for Hazardous
Location use.
• PWR-HV-NP: one 110/220 VAC/VDC (90 to 264 VAC, 88 to 300
VDC) power input.
• PWR-LV-NP: one 24/48 VDC (18 to 72 VDC) power input.
For the PWR-HV-P48, the 110/220 VAC/VDC power supplies provide
power to the switch. Separate 48 VDC power supplies are required to
provide power to all PoE+ ports (50 to 57 VDC is recommended for
IEEE 802.3at devices. The max. PoE output from an external power
supply is 720 W when the operating temperature is under 60°C; 360 W
when the operating temperature is under 75°C.).
For the PWR-LV-P48 models, the 24/48 VDC power supplies provide
power to the switch. Separate 48 VDC power supplies are required to
provide power to all PoE+ ports (50 to 57 VDC is recommended for
IEEE 802.3at devices. The max. PoE output from an external power
supply is 720 W when the operating temperature is under 60°C; 360 W
when the operating temperature is under 75°C.).