Installation Guide
Table Of Contents
- MDS-G4000/MDS-G4000-L3 Series Quick Installation Guide
- Package Checklist
- Default Settings
- Panel Layouts
- Dimensions
- Ethernet Modules (Hardware Rev.2.0.0 and above)
- Power Modules (Hardware Rev.2.1.0 and above)
- DIN-rail Dimensions and Instructions
- Wall-mounting Dimensions and Instructions (Optional: WK-112-01)
- Rack-mounting Dimensions and Instructions (Optional: RK-3U-02)
- Matters That Require Attention
- Connecting the Power Inputs
- Power Terminal Blocks
- PoE Power Terminal Blocks
- Wiring the Relay Contact
- Digital Input/Output
- Installing and Removing the Ethernet Modules
- Installing and Removing the Power Modules
- Grounding the Moxa Industrial DIN-rail Switch
- RS-232 with RJ45 Interface Console Connection
- USB Connection
- Reset to Factory Default Settings
- LED Indicators
- Specifications
- Supported SFP Modules
- Restricted Access Locations
- Special Conditions of Use
- Hazardous Location Usage Terms
- 22 -
Module
Description
SFP-1GTXRJ45-T SFP module with 1 1000BaseT port with RJ45
connector for 100 m transmission, -40 to 75°C
operating temperature
Note: This module is not certified for Hazardous
Location.
Restricted Access Locations
• This equipment is intended to be used in Restricted Access
Locations, such as a computer room, with access limited to service
personnel or users who have been instructed on how to handle the
metal chassis of equipment that is very hot. The location should
only be accessible with a key or through a security system.
• External metal parts of this equipment are extremely
hot. Before touching the equipment, you must take
special precautions to protect your hands and body
from serious injury.
Special Conditions of Use
• The equipment shall only be used in an area of at least pollution
degree 2, as defined in EN 60664-1.
• The equipment shall be installed in an enclosure that provides a
degree of protection not less than IP 54 in accordance with EN
60079-0 and accessible only by the use of a tool.
• Transient protection device with capability of voltage clamping
rating less than 119Vdc shall be provided externally of the PWR
voltage supply terminal.
ATTENTION
T
hese devices are open-type devices that are to be installed in
an enclosure with tool
-
removable cover or door, suitable for the
environment.
This equipment is suitable for use in Class I, Division 2, Groups
A, B, C, and D or non-hazardous locations only.
WARNING
—EXPLOSION HAZARD
Do not disconnect equipment unless power has been removed
or the area is known to be non
-hazardous.
Substitution of any components may impair suitability for Class
I, Division 2.